The series pulse-proof resistors on the A and B bus lines limit the
residual clamping current the transceiver sees if the TVS clamping
voltage is higher than the specified maximum voltage of the
transceiver bus pins. These resistors are typically very low in
value (~10-20Ω) and should be selected to accommodate the
appropriate power levels