Dainis (30.01.2005 22:29, просмотров: 1) ответил д__ на У меня тоже: оцд коммандер дает ошибку 43, и небыло времени углупиться в проблему...
Ответ: error 43 One note about the new versions of ocdremote (>2.07) - make sure the parallel port connector has a link between pins 8 and 15. The newer versions check this. If it is not present they fail with internal error 43.
BTW. Reading JTAG Tools docs I have found out how to connect nTRST signal
(JTAG TAP reset): DB25 pin 6 -> a buffer -> IDC20 pin 3.
Arie de Munck sent me a schematic of an interface that had a link between
pins 8 and 15 on the DB-25 connector. I added this link to my interface and
it works OK with the current version of OCD Commander. It looks as though
the software wasn't checking this link, previously. I've added the link to
my interface schematic and PCB.