Mikla (17.04.2012 17:00, просмотров: 139) ответил Юрий_СВ на Интересует только 8031. А есть где-нибудь описание ошибок ? (8031 уже куплена, под заказ)
Revision ID is changed from ‘0x1555’ in Rev. A to ‘0x1556’ in Rev. A2.
For customer software that needs to access the
Revision ID information, software change might
be needed.
2
For RMII 50MHz clock in mode, the hold time is
now 2ns (min), compliant to RMII specification
V1.2.
In Rev. A, the required RMII hold time for the
TXEN and TXD[1:0] inputs is 8ns (min).
Applies to KSZ8021/8031/8051 devices that
operate in RMII 50MHz clock in mode.
3
Fixed the issue with regard to the Re-start Autonegotiation
bit.
For Rev. A devices, after power-up, the Re-start
Auto-negotiation bit (register 0, bit [9]) may fail to
work properly to initialize the auto-negotiation
state machine, resulting in link failure.
The Re-start Auto-negotiation bit can be used in
Rev. A2 now.