ВходНаше всё Теги codebook 无线电组件 Поиск Опросы Закон Понедельник
25 ноября
339932 Топик полностью
Flg (10.07.2012 18:15, просмотров: 1) ответил zeleny на как проинвертировать RS485-TXEN в CP2103 ?
Это не та галочка.Using a CP210x with RS-485Question How do I use a CP210x device with a RS-485 transceiver?Answer The CP2103 has native support for interfacing with RS-485. To use this feature, the CP2103 GPIO.2 pin should be configured for "A - Automatic by Device" using the AN223 CP210x Port Configuration utility. This pin should be connected to a RS-485 transceiver's transmit-enable pin. Since this signal is active-low, a RS-485 transceiver with active-low transmit-enable should be chosen. If using an RS-485 transceiver with an active-high transmit-enable, then an inverter will be necessary. Another way to use RS-485 with any CP210x device is to open the COM port in "Transmit Active" mode. When using the device in this way, the following pin connections should be made: RS-485 Transceiver's Transmit-Enable to CP210x RTS RS-485 Transceiver's Receive-Enable to CP210x Suspend Application Notes can be found on the Silicon Laboratories Applications webpage: https://www.silabs …181646&n=1&docid=21730