На вход ОУ -- что приходит, с какой амплитудой? Процитирую: http://www.ti.com/lit/an/sboa092b/sboa092b.pdf
1) "The open loop amplifier is not practical - once an op amp (его выход) is pushed to saturation, its behavior is unpredictable. Recovery time from saturation is not specified for op amps (except voltage limiting types). It may not recover at all; the output may latch up..." (C) Texas Instruments. 2) "The Common Mode Voltage Limit. As stated above, the circuitry within the operational amplifier responds to the voltages appearing at the two inputs separately. Either input can be overdriven, saturating the input transistor(s) (что может повлечь деградацию скоростных характеристик и искажение сигнала)... Since under normal feedback conditions there is only a negligible difference in voltage between the two inputs (see “Summing Point Restraints”), the input saturation voltage is known as the common mode voltage limit and appears in Texas Instruments specifications. " Т.е. что я хочу сказать -- проблема может быть обусловлена слишком высокой амплитудой входного сигнала сигнала. По какой схеме включен оптрон относительно операционника? Эмиттер на землю, резистор к VCC операционника, коллектор к резистору? Имеем насыщение входа, ну и выхода тоже, и замедленную реакцию транзисторов в обоих случаях (LM328 биполярный). Если наоборот, "с общим коллектором", то ещё хуже. Можно попробовать (если эмиттером к земле) параллельно транзистору оптрона (или входу ОУ) запаять на землю резистор в ~два раза большего сопротивления, чем стоит с коллектора на VCC (чтоб выход делителя всегда был < Vcc - 1.5в). И проверить осциллографом, что на входе ОУ сигнал не выходит за maximum ratings.
[ZX]
1) "The open loop amplifier is not practical - once an op amp (его выход) is pushed to saturation, its behavior is unpredictable. Recovery time from saturation is not specified for op amps (except voltage limiting types). It may not recover at all; the output may latch up..." (C) Texas Instruments. 2) "The Common Mode Voltage Limit. As stated above, the circuitry within the operational amplifier responds to the voltages appearing at the two inputs separately. Either input can be overdriven, saturating the input transistor(s) (что может повлечь деградацию скоростных характеристик и искажение сигнала)... Since under normal feedback conditions there is only a negligible difference in voltage between the two inputs (see “Summing Point Restraints”), the input saturation voltage is known as the common mode voltage limit and appears in Texas Instruments specifications. " Т.е. что я хочу сказать -- проблема может быть обусловлена слишком высокой амплитудой входного сигнала сигнала. По какой схеме включен оптрон относительно операционника? Эмиттер на землю, резистор к VCC операционника, коллектор к резистору? Имеем насыщение входа, ну и выхода тоже, и замедленную реакцию транзисторов в обоих случаях (LM328 биполярный). Если наоборот, "с общим коллектором", то ещё хуже. Можно попробовать (если эмиттером к земле) параллельно транзистору оптрона (или входу ОУ) запаять на землю резистор в ~два раза большего сопротивления, чем стоит с коллектора на VCC (чтоб выход делителя всегда был < Vcc - 1.5в). И проверить осциллографом, что на входе ОУ сигнал не выходит за maximum ratings.