- The series pulse-proof resistors on the A and B bus lines limit the residual clamping current the transceiver sees if the TVS clamping voltage is higher than the specified maximum voltage of the transceiver bus pins. These resistors are typically very low in value (~10-20Ω) and should be selected to accommodate the appropriate power levels - Alex68(24.03.2023 00:35)